It certainly could. One of the most useful lessons in operating an anaerobic digestion (AD) plant is that the trend in a measurement can be more revealing than the measurement itself.
A digester temperature may still be within its permitted operating range, but it has been falling steadily for three days. Methane concentration may remain acceptable, but it is gradually declining. A feed pump may still be running, but its electrical demand has increased unexpectedly.
None of these observations necessarily means that a failure is imminent. However, each could provide an early warning that deserves investigation.
For operators responsible for maintaining reliable biogas production, a few minutes spent reviewing daily operating records can be extremely valuable.
1. Methane Production: Look Beyond Total Biogas Volume
Daily biogas production is one of the most familiar measurements on an AD plant. But total gas volume alone does not tell the whole story.
For example, suppose a plant normally produces 5,000 cubic metres of biogas per day at 60% methane.
That represents approximately 3,000 cubic metres of methane per day, before any necessary correction for gas measurement conditions.
If biogas production remains at 5,000 cubic metres but methane concentration falls to 55%, the calculated methane volume becomes 2,750 cubic metres per day.
That is a reduction of approximately 8.3% in methane production, even though the total biogas volume has not changed.
The cause might involve feedstock composition, biological performance, measurement error or other operating conditions.
The important point is that a trend in methane output can reveal something that total gas volume alone may conceal.
Daily operator check: Record biogas volume, methane concentration and calculated methane production, using consistent gas-volume measurement conditions.
2. Feedstock Loading: Tonnes Per Day Can Be Misleading
Many AD operators record the weight or volume of feedstock delivered to the digester each day.
That is essential information, but it may not adequately describe the organic load imposed on the biological process.
Consider two deliveries of food waste slurry, each weighing 20 tonnes.
One contains 10% dry solids, while the other contains 15% dry solids.
The first contains approximately two tonnes of dry matter. The second contains three tonnes.
Assuming similar volatile solids proportions, the second delivery could impose a substantially greater organic load despite having exactly the same wet weight.
Differences in biodegradability, fat content, nutrients and potential inhibitors can complicate the picture further.
This is why organic loading rate, expressed in kilograms of volatile solids per cubic metre of working digester volume per day, is generally more informative than wet tonnes alone.
Not every plant measures feedstock volatile solids daily. However, operators should use the best available feedstock analyses and record changes in supply, appearance, consistency and composition.
Daily operator check: Record feedstock quantity and type, note unusual deliveries and compare loading with the plant's established operating limits.
3. Digester Temperature: Small Changes May Matter
Temperature stability is fundamental to anaerobic digestion.
Mesophilic digesters commonly operate around 35–40°C, although the appropriate operating temperature depends on the plant's design and biological process.
Operators sometimes concentrate on whether the current temperature remains within the permitted range.
But consider a digester that normally operates at 38°C.
Its recorded temperature falls to 37.7°C, then 37.4°C, then 37.1°C over successive days.
Those readings may not activate an alarm, but the downward trend suggests that something has changed.
Possible explanations include reduced heat input, fouling of heat-transfer surfaces, inadequate circulation, colder incoming feedstock or an instrumentation problem.
The appropriate response is to investigate the cause rather than simply increasing the heating set point.
Temperature readings should also be considered alongside heating-system operation and, where available, measurements from different locations within the digester.
Daily operator check: Record temperature trends and investigate unexplained deviations from the plant's normal operating pattern.
4. Biological Stability: Watch the Indicators, Not Just the pH
Biological instability can develop before a dramatic change in digester pH becomes apparent.
This is partly because a digester's buffering capacity can temporarily resist changes in acidity.
Volatile fatty acids (VFAs), alkalinity and their relationship can therefore provide useful information about the balance between acid production and methane formation.
A sustained rise in VFAs, particularly when accompanied by changes in alkalinity or methane production, may indicate that the biological process is becoming stressed.
However, no single VFA concentration or ratio provides a universal diagnosis for every digester.
Results must be interpreted in relation to feedstock characteristics, operating history, analytical methods and other process measurements.
Nor is daily laboratory analysis necessary or practical at every AD plant.
The sampling frequency should reflect the plant's monitoring programme, risk profile and current operating conditions.
Daily operator check: Review the latest available biological monitoring results, record any new abnormalities and ensure that required samples and tests are completed on schedule.
5. Equipment Performance: Mechanical Problems Often Develop Gradually
Not every threat to biogas production begins inside the biological process.
Mechanical equipment can deteriorate gradually while continuing to operate.
A pump may require increasing power to deliver the same flow. A heat exchanger may transfer progressively less heat. A mixer may develop unusual vibration or operate outside its normal electrical load.
These changes may indicate developing restrictions, wear, fouling or other mechanical problems.
However, electrical current alone is not a reliable measure of equipment condition. Changes in slurry properties, operating speed and process demand must also be considered.
Where suitable monitoring is installed, useful observations include:
- Motor current or measured electrical power.
- Pump flow and discharge pressure.
- Mixer operating status and abnormal vibration.
- Heat-exchanger inlet and outlet temperatures.
- Unusual noise, leakage or repeated equipment trips.
Daily operator check: Compare equipment readings and observations with normal operating conditions, and report unexplained changes before they become failures.
A Practical Example: When Methane Production Starts Falling
Imagine an AD plant where daily methane production has fallen by 6% over the previous week.
The control system has not generated a major alarm, and the digester temperature remains within its operating range.
What should the operator do?
The sensible response is not immediately to increase feedstock loading or alter the biological process.
Instead, the operator should review the evidence:
- Check that gas flow and methane concentration measurements are reliable.
- Compare recent feedstock deliveries and organic loading with previous records.
- Examine temperature trends and heating-system performance.
- Review the latest VFA, alkalinity and other relevant biological results.
- Check for changes in mixing, pumping, gas handling or equipment availability.
There may be several possible explanations. The feedstock could have changed. A gas analyser might require attention. The biological process may be responding to a change in loading, or mechanical problems may be affecting performance.
The value of daily records is that they help narrow the investigation before corrective action is taken.
Why Yesterday's Reading Is Often More Useful Than a Fixed Alarm Limit
Automatic alarms are essential safeguards, but they cannot replace informed operational supervision.
Alarms are generally configured to identify conditions that exceed defined limits or meet specific fault criteria.
A developing problem may remain below those limits for some time.
By reviewing daily measurements alongside previous results, operators can recognise unusual patterns that deserve attention.
This does not mean reacting to every small fluctuation. Biological systems naturally vary, and instruments have measurement uncertainty.
The skill lies in distinguishing normal variation from sustained, unexplained changes.
Good operating records make that judgement easier.
Make Daily Monitoring a Habit, Not a Paperwork Exercise
A useful daily checklist should be straightforward enough to complete consistently.
It should identify the essential observations, provide space for unusual conditions and make clear when further investigation or escalation is required.
Automated monitoring systems can supply much of the numerical data, while operators contribute observations that instruments may not detect.
The most effective approach combines reliable measurements, practical experience and consistent record-keeping.
The purpose is not to collect more figures. It is to turn operating information into timely decisions.
Conclusion: Five Readings, One Important Principle
Methane production, feedstock loading, digester temperature, biological stability and equipment performance are all important aspects of AD plant operation.
But the greatest value often comes from examining how these measurements change together.
A single unusual reading may mean very little. A consistent trend supported by several independent observations can provide a much stronger reason to investigate.
For biogas plant operators, that is the practical value of disciplined daily monitoring.
Recognising a developing problem early is usually preferable to discovering it after methane production has fallen or equipment has failed.
Free Up Your Time with a Structured Daily Operating Worksheet
If you operate or supervise an anaerobic digestion plant, a consistent daily record can make monitoring easier and help identify changes that deserve attention.
The Biogas Plant Operator's Daily Worksheet is designed to provide a practical structure for recording routine operating information and observations.
The worksheet is a supporting operational resource. It does not replace site-specific procedures, equipment instructions, statutory requirements or competent technical supervision.
Article by Steve Last, MICE, MCIWM, CEnv – Chartered Civil and Environmental Engineer, Chartered Waste Manager and Principal of IPPTS Associates.


0 Comments